[. . . ] The Da-Lite Difference.
Installation and Operating Instructions For
SIngle MOtOr lOw VOltage COntrOl SySteM
DA-LITE SCREEN COMPANY, INC.
3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax: 574-267-7804 www. da-lite. com e-mail: info@da-lite. com
thelowvoltagecontrol(LVC)housingisdividedinto3compartments. thecompartmentlabeled"LowVoltage Connections"iswhereyouwillconnectthewallswitchoracentralcontrolpanel. thecompartmentlabeled"ACPower Connections"iswherethemainpowerandmotorwireconnectionsaremade. thecentercompartmentonlyrequires accesswhenconnectinganinfraredorradiofrequencyremotereceiver.
INSTALLATION
WARNING: topreventelectricalshockordamagetotheLVC, donotapplypowertotheLVCuntilallconnectionsare complete. Makesurepoweristurnedoffonallwiresbeforemakingconnections. LOW VOLTAGE CONNECTIONS: Wall Switch WARNING: thisunitmustbeusedwiththeenclosedswitch. DONOtUSetherockerswitchincludedwithscreen. [. . . ] Amomentaryclosureacrossthewhite, redandblackwireswillbea"stop"command.
!s
CAUTION: Never apply voltage to the wall switch lead or the LVC will be damaged.
white
Diagram 1
bLACk
bLACk
ReD
UP
Recommended Wire Size: 20-24 AWG
LOw-VOLtAGe wALLSwitCh
STOP DOWN
AC POWER CONNECTIONS: Screen Motor 1. ConnectthemotorwiresinthescreenjunctionboxtotheLVCwireslabeled"motorwires" . Refertodiagram2. Use14-18gaugewiretoextendthemotorwiretotherequiredlength.
GReeN GROUND
120VAC 60Hz
GROUNDLUG
GReeN/yeLLOw GROUND
240 VAC 50Hz
GROUNDLUG
SCReeN whitewhite bLACk-bLACk ReD-ReD
SCReeN bLUebLUe bROwN-bROwN bLACk-bLACk
UP STOP
UP STOP
Diagram 2
Recommended Wire Size: 14-18 AWG
DOWN
Recommended Wire Size: 14-18 AWG
1
DOWN
INSTALLATION
AC Power Source 1. ConnectpowerwirestotheLVCwireslabeled"ACpowerinput" . Refertodiagram3. Connectthebuildinggroundwiretothegroundlugonthemetalhousing.
bLACkbLACk whitewhite
GReeNGROUND GROUNDLUG
UP STOP
BROWN HOT bLUe COMMON
GReeNGROUND GROUNDLUG
UP STOP
Diagram 3
POweR SOURCe 120VAC 60hZ
Recommended Wire Size: 14-18 AWG
DOWN
POweR SOURCe 240VAC 50hZ
Recommended Wire Size: 14-18 AWG
DOWN
OPTIONAL WIRELESS REMOTE CONNECTIONS: Radio Frequency Remote 1. Removethecoverplatelabeled"Lowvoltageconnections"andthecentercoverplate. Routethereceiverwirethroughtheroundplasticbushingandplugitintotheonboardsocketmarked"eye" . Refer todiagram4. Removethecoverplatelabeled"Lowvoltageconnections"andthecentercoverplate. Routethereceiverwirethroughtheroundplasticbushingandplugitintotheonboardsocketmarked"eye" . Refer todiagram4.
120VAC60hZ
OPtiONALRFOR iRReMOteCONNeCtOR
240VAC50hZ
OPtiONALRFOR iRReMOteCONNeCtOR
EYE AUX
Diagram 4
2
AUX EYE
TROUBLESHOOTING
NOTE: The LVC will shut off power to the screen motor 5 minutes after the motor stops turning. [. . . ] (a) turnoffpowertoLVC. Reverse theredandblackwiresoneither themotorterminalsorthewall switchterminals. Changingeither onewillchangethedirectionof motortravel. Donotchange both.
(d)
2. Screenrunsinthewrong direction.
PrintedinU. S. A.
3
98885Rev. 6/06 [. . . ]